参考号 | 零件 | 参数 |
---|---|---|
DIEDERICHS : DCG1000 | Interior Blower | Voltage: 13.5 V; Rated Power: 236 W; Service RPM: 3100 1/min; : E-type checked ; : for vehicles with air conditioning ; Current-carrying capacity: 17.5 A; |
DIEDERICHS : DCG1001 | Interior Blower | Voltage: 13.5 V; Rated Power: 230 W; Current-carrying capacity: 17 A; Service RPM: 3500 1/min; |
DIEDERICHS : DCG1002 | Interior Blower | Voltage: 13.5 V; Rated Power: 338 W; Service RPM: 4000 1/min; : for vehicles with air conditioning ; Current-carrying capacity: 25 A; |
DIEDERICHS : DCG1003 | Interior Blower | Voltage: 13.5 V; Rated Power: 243 W; Service RPM: 3650 1/min; : for vehicles with air conditioning ; Current-carrying capacity: 18 A; |
DIEDERICHS : DCG1004 | Interior Blower | Voltage: 13.5 V; : for vehicles with air conditioning ; |
DIEDERICHS : DCG1005 | Interior Blower | Voltage: 13.5 V; : for vehicles without air conditioning ; |
DIEDERICHS : DCG1006 | Interior Blower | Voltage: 13.5 V; Rated Power: 243 W; Number of connectors: 2 ; Current-carrying capacity: 18 A; Service RPM: 3400 1/min; : E-type checked ; |
DIEDERICHS : DCG1007 | Interior Blower | Voltage: 13.5 V; Rated Power: 324 W; Knobs: 2 ; : for vehicles with/without air conditioning ; Current-carrying capacity: 24 A; Service RPM: 3800 1/min; : E-type checked ; |
DIEDERICHS : DCG1008 | Interior Blower | Voltage: 13.5 V; Rated Power: 320 W; Knobs: 2 ; : for vehicles with automatic climate control ; Current-carrying capacity: 24 A; Service RPM: 3800 1/min; : E-type checked ; |
DIEDERICHS : DCG1009 | Interior Blower | Voltage: 13.5 V; Rated Power: 320 W; : for vehicles with air conditioning ; : with load resistor ; Current-carrying capacity: 24 A; Service RPM: 3800 1/min; |
DIEDERICHS : DCG1010 | Interior Blower | Voltage: 13.5 V; Rated Power: 270 W; : for vehicles with/without air conditioning ; : with load resistor ; Current-carrying capacity: 20 A; Service RPM: 3500 1/min; : E-type checked ; |
DIEDERICHS : DCG1011 | Interior Blower | Voltage: 13.5 V; Rated Power: 225 W; : for vehicles without air conditioning ; |
DIEDERICHS : DCG1012 | Interior Blower | Voltage: 13.5 V; : E-type checked ; : for vehicles with air conditioning ; |
DIEDERICHS : DCG1013 | Interior Blower | Voltage: 13.5 V; Rated Power: 223 W; : for vehicles with air conditioning ; : with load resistor ; Current-carrying capacity: 16.5 A; Service RPM: 3450 1/min; |
DIEDERICHS : DCG1014 | Interior Blower | Voltage: 13.5 V; Rated Power: 223 W; Current-carrying capacity: 16.5 A; Service RPM: 4450 1/min; : for vehicles with air conditioning ; |
DIEDERICHS : DCG1015 | Interior Blower | Voltage: 13.5 V; Rated Power: 466 W; Service RPM: 3200 1/min; : for vehicles with/without air conditioning ; Current-carrying capacity: 34.5 A; |
DIEDERICHS : DCG1016 | Interior Blower | Voltage: 13.5 V; Rated Power: 405 W; Service RPM: 3400 1/min; : for vehicles with air conditioning ; Current-carrying capacity: 30 A; |
DIEDERICHS : DCG1017 | Interior Blower | Voltage: 13.5 V; : for vehicles with/without air conditioning ; : with load resistor ; Current-carrying capacity: 20.5 A; Minimum Volume: 277 cm³/l; Service RPM: 2450 1/min; |
DIEDERICHS : DCG1018 | Interior Blower | Voltage: 13.5 V; Rated Power: 270 W; Service RPM: 3700 1/min; : E-type checked ; Number of connectors: 2 ; : without load resistor ; Current-carrying capacity: 20 A; |
DIEDERICHS : DCG1019 | Interior Blower | Voltage: 13.5 V; Rated Power: 216 W; Service RPM: 3400 1/min; : for vehicles with/without air conditioning ; : with load resistor ; Current-carrying capacity: 16 A; |
DIEDERICHS : DCG1020 | Interior Blower | Voltage: 13.5 V; Rated Power: 398 W; Service RPM: 3500 1/min; : for vehicles with/without air conditioning ; Current-carrying capacity: 29.5 A; |
DIEDERICHS : DCG1021 | Interior Blower | Voltage: 13.5 V; Rated Power: 378 W; : E-type checked ; : for vehicles with air conditioning ; Number of connectors: 2 ; Current-carrying capacity: 28 A; Service RPM: 3600 1/min; |
DIEDERICHS : DCG1022 | Interior Blower | Voltage: 13.5 V; Rated Power: 446 W; : for vehicles with air conditioning ; Current-carrying capacity: 33 A; Service RPM: 3600 1/min; |
DIEDERICHS : DCG1023 | Interior Blower | Voltage: 13.5 V; |
DIEDERICHS : DCG1024 | Interior Blower | Voltage: 13.5 V; Rated Power: 243 W; : E-type checked ; : for vehicles without air conditioning ; Current-carrying capacity: 18 A; Service RPM: 3460 1/min; |
DIEDERICHS : DCG1025 | Interior Blower | Voltage: 13.5 V; Rated Power: 311 W; : for vehicles with air conditioning ; Current-carrying capacity: 23 A; Service RPM: 3550 1/min; |
DIEDERICHS : DCG1026 | Interior Blower | Voltage: 13.5 V; Rated Power: 284 W; : with load resistor ; Current-carrying capacity: 21 A; Service RPM: 3600 1/min; : for vehicles with air conditioning ; : with control unit ; |
DIEDERICHS : DCG1027 | Interior Blower | Voltage: 13.5 V; Rated Power: 339 W; : for vehicles with air conditioning ; Current-carrying capacity: 25.1 A; Service RPM: 3750 1/min; : E-type checked ; |
DIEDERICHS : DCG1028 | Interior Blower | Voltage: 13.5 V; Rated Power: 243 W; Service RPM: 4850 1/min; : for vehicles with/without air conditioning ; Current-carrying capacity: 17 A; |
DIEDERICHS : DCG1029 | Interior Blower | Voltage: 13.5 V; Service RPM: 4330 1/min; : for vehicles with air conditioning ; Current-carrying capacity: 14.8 A; Minimum Volume: 200 cm³/l; |
DIEDERICHS : DCG1030 | Interior Blower | Voltage: 13.5 V; Rated Power: 162 W; Service RPM: 3150 1/min; : E-type checked ; : for vehicles with/without air conditioning ; Current-carrying capacity: 12 A; |
DIEDERICHS : DCG1031 | Interior Blower | Voltage: 13.5 V; Rated Power: 200 W; |
DIEDERICHS : DCG1032 | Interior Blower | Voltage: 13.5 V; Rated Power: 257 W; Service RPM: 3650 1/min; : for vehicles with/without air conditioning ; Current-carrying capacity: 19 A; |
DIEDERICHS : DCG1033 | Interior Blower | Voltage: 13.5 V; Rated Power: 257 W; Service RPM: 3050 1/min; : for vehicles without air conditioning ; Current-carrying capacity: 19 A; |
DIEDERICHS : DCG1034 | Interior Blower | Voltage: 13.5 V; Rated Power: 230 W; Service RPM: 3500 1/min; Current-carrying capacity: 17 A; |
DIEDERICHS : DCG1035 | Interior Blower | Voltage: 13.5 V; Rated Power: 311 W; Service RPM: 3870 1/min; : for vehicles with/without air conditioning ; Current-carrying capacity: 23 A; |
DIEDERICHS : DCG1036 | Interior Blower | Voltage: 13.5 V; Rated Power: 385 W; Service RPM: 3800 1/min; : for vehicles with air conditioning ; Current-carrying capacity: 28.5 A; |
DIEDERICHS : DCG1037 | Interior Blower | Voltage: 13.5 V; Rated Power: 189 W; Service RPM: 3600 1/min; : for vehicles with air conditioning ; Current-carrying capacity: 14 A; |
DIEDERICHS : DCG1038 | Interior Blower | Voltage: 13.5 V; Rated Power: 331 W; Service RPM: 3400 1/min; : for vehicles without air conditioning ; Current-carrying capacity: 24.5 A; |
DIEDERICHS : DCG1039 | Interior Blower | Voltage: 13.5 V; Rated Power: 196 W; Current-carrying capacity: 14.5 A; Service RPM: 3200 1/min; : for vehicles without air conditioning ; |
DIEDERICHS : DCG1040 | Interior Blower | Voltage: 13.5 V; Rated Power: 200 W; Service RPM: 3050 1/min; : for vehicles without air conditioning ; Current-carrying capacity: 14.8 A; |
DIEDERICHS : DCG1041 | Interior Blower | Voltage: 13.5 V; Rated Power: 297 W; Service RPM: 3300 1/min; : for vehicles with air conditioning ; Current-carrying capacity: 22 A; |
DIEDERICHS : DCG1042 | Interior Blower | Voltage: 13.5 V; Rated Power: 262 W; Service RPM: 3400 1/min; : for vehicles with air conditioning ; Current-carrying capacity: 19.4 A; |
DIEDERICHS : DCG1043 | Interior Blower | Voltage: 13.5 V; |
DIEDERICHS : DCG1044 | Interior Blower | Voltage: 13.5 V; |
DIEDERICHS : DCG1045 | Interior Blower | Voltage: 13.5 V; Service RPM: 3300 1/min; : for vehicles with air conditioning ; Current-carrying capacity: 23 A; Minimum Volume: 311 cm³/l; |
DIEDERICHS : DCG1046 | Interior Blower | Voltage: 13.5 V; |
DIEDERICHS : DCG1047 | Interior Blower | Voltage: 13.5 V; Rated Power: 256.5 W; Service RPM: 3350 1/min; : for vehicles with/without air conditioning ; Current-carrying capacity: 19 A; |
DIEDERICHS : DCG1048 | Interior Blower | Voltage: 13.5 V; Rated Power: 182 W; : for vehicles with/without air conditioning ; Current-carrying capacity: 13.5 A; Service RPM: 3950 1/min; |
DIEDERICHS : DCG1049 | Interior Blower | Voltage: 13.5 V; Rated Power: 256.5 W; Number of connectors: 2 ; Current-carrying capacity: 19 A; Service RPM: 3400 1/min; : E-type checked ; |
DIEDERICHS : DCG1050 | Interior Blower | Voltage: 13.5 V; Rated Power: 259 W; Service RPM: 3600 1/min; : for vehicles with/without air conditioning ; Current-carrying capacity: 19.2 A; |
DIEDERICHS : DCG1051 | Interior Blower | Voltage: 13.5 V; Rated Power: 216 W; Current-carrying capacity: 16 A; Service RPM: 3100 1/min; : E-type checked ; : for vehicles with air conditioning ; Number of connectors: 2 ; |
DIEDERICHS : DCG1052 | Interior Blower | Voltage: 13.5 V; Rated Power: 270 W; Current-carrying capacity: 20 A; Observe illustration: ; for OE No.: A2048200008 ; Service RPM: 4450 1/min; : for vehicles with air conditioning ; |
DIEDERICHS : DCG1053 | Interior Blower | Voltage: 13.5 V; |
DIEDERICHS : DCG1054 | Interior Blower | Voltage: 13.5 V; Rated Power: 540 W; Number of connectors: 2 ; Current-carrying capacity: 40 A; Service RPM: 3200 1/min; : E-type checked ; |
DIEDERICHS : DCG1055 | Interior Blower | Voltage: 13.5 V; Rated Power: 270 W; : for vehicles with air conditioning ; Current-carrying capacity: 20 A; for OE No.: A2128200708 ; Service RPM: 4250 1/min; |
DIEDERICHS : DCG1056 | Interior Blower | Voltage: 13.5 V; Rated Power: 419 W; Service RPM: 3270 1/min; : for vehicles with/without air conditioning ; Current-carrying capacity: 31 A; |
DIEDERICHS : DCG1057 | Interior Blower | Voltage: 13.5 V; Rated Power: 580.5 W; Current-carrying capacity: 43 A; Service RPM: 3300 1/min; : E-type checked ; : for vehicles with automatic climate control ; Number of connectors: 2 ; |
DIEDERICHS : DCG1058 | Interior Blower | Voltage: 13.5 V; Rated Power: 270 W; Current-carrying capacity: 20 A; Service RPM: 3200 1/min; : E-type checked ; Number of connectors: 2 ; |
DIEDERICHS : DCG1059 | Interior Blower | Voltage: 13.5 V; Rated Power: 311 W; Service RPM: 3870 1/min; : for vehicles with/without air conditioning ; Current-carrying capacity: 23 A; |
DIEDERICHS : DCG1060 | Interior Blower | Voltage: 13.5 V; Rated Power: 196 W; Service RPM: 3200 1/min; : for vehicles without air conditioning ; Current-carrying capacity: 14.5 A; |
DIEDERICHS : DCG1061 | Interior Blower | Voltage: 13.5 V; Rated Power: 230 W; Service RPM: 3600 1/min; : for vehicles with air conditioning ; Current-carrying capacity: 17 A; |
DIEDERICHS : DCG1062 | Interior Blower | Voltage: 13.5 V; Trim Level: Basic Design ; |
DIEDERICHS : DCG1063 | Interior Blower | Voltage: 13.5 V; Trim Level: Deluxe Design ; |
DIEDERICHS : DCG1064 | Interior Blower | Voltage: 13.5 V; Rated Power: 351 W; Service RPM: 2700 1/min; : for vehicles without air conditioning ; Current-carrying capacity: 26 A; |
DIEDERICHS : DCG1065 | Interior Blower | Voltage: 13.5 V; Rated Power: 446 W; Service RPM: 3150 1/min; : for vehicles with air conditioning ; Current-carrying capacity: 33 A; |
DIEDERICHS : DCG1066 | Interior Blower | Voltage: 13.5 V; Rated Power: 230 W; Service RPM: 3950 1/min; : for vehicles with/without air conditioning ; Current-carrying capacity: 17 A; |
DIEDERICHS : DCG1067 | Interior Blower | Voltage: 13.5 V; Rated Power: 178 W; Current-carrying capacity: 13.2 A; Service RPM: 3300 1/min; : for vehicles without air conditioning ; |
DIEDERICHS : DCG1068 | Interior Blower | Voltage: 13.5 V; Rated Power: 254 W; Service RPM: 3660 1/min; : for vehicles with air conditioning ; Current-carrying capacity: 18.8 A; |
DIEDERICHS : DCG1069 | Interior Blower | Voltage: 13.5 V; Rated Power: 173 W; |
DIEDERICHS : DCG1070 | Interior Blower | Voltage: 13.5 V; : E-type checked ; Connector Shape: round ; |
DIEDERICHS : DCG1071 | Interior Blower | Voltage: 13.5 V; Rated Power: 263 W; Service RPM: 3600 1/min; : for vehicles with/without air conditioning ; Connector Shape: angular ; Current-carrying capacity: 19.5 A; |
DIEDERICHS : DCG1072 | Interior Blower | Voltage: 13.5 V; Rated Power: 243 W; Service RPM: 3200 1/min; : E-type checked ; : for vehicles with air conditioning ; Current-carrying capacity: 18 A; |
DIEDERICHS : DCG1073 | Interior Blower | Voltage: 13.5 V; Rated Power: 311 W; Service RPM: 3900 1/min; Current-carrying capacity: 23 A; |
DIEDERICHS : DCG1074 | Interior Blower | Voltage: 13.5 V; Rated Power: 317 W; Service RPM: 3000 1/min; : for vehicles with/without air conditioning ; Current-carrying capacity: 23.5 A; |
DIEDERICHS : DCG1075 | Interior Blower | Voltage: 13.5 V; Rated Power: 401 W; Service RPM: 3050 1/min; : for vehicles with air conditioning ; Current-carrying capacity: 29.7 A; |
DIEDERICHS : DCG1076 | Interior Blower | Voltage: 13.5 V; Rated Power: 270 W; Service RPM: 4650 1/min; : E-type checked ; : for vehicles with/without air conditioning ; Current-carrying capacity: 20 A; |
DIEDERICHS : DCG1077 | Interior Blower | Voltage: 13.5 V; : for vehicles without air conditioning ; |
DIEDERICHS : DCG1078 | Interior Blower | Voltage: 13.5 V; : for vehicles with air conditioning ; |
DIEDERICHS : DCG1079 | Interior Blower | Voltage: 13.5 V; Rated Power: 324 W; Number of connectors: 2 ; Current-carrying capacity: 24 A; Service RPM: 3400 1/min; : for vehicles with air conditioning ; |
DIEDERICHS : DCG1080 | Interior Blower | Voltage: 13.5 V; Rated Power: 392 W; Current-carrying capacity: 29 A; Service RPM: 3450 1/min; : for vehicles with/without air conditioning ; |
DIEDERICHS : DCG1081 | Interior Blower | Voltage: 13.5 V; Rated Power: 459 W; Service RPM: 3200 1/min; : for vehicles with/without air conditioning ; Current-carrying capacity: 34 A; |
DIEDERICHS : DCG1082 | Interior Blower | Voltage: 13.5 V; Rated Power: 290 W; Service RPM: 3550 1/min; : for vehicles with/without air conditioning ; Current-carrying capacity: 21.5 A; |
DIEDERICHS : DCG1083 | Interior Blower | Voltage: 13.5 V; Rated Power: 331 W; Service RPM: 3750 1/min; : for vehicles with air conditioning (manually controlled) ; Current-carrying capacity: 25.5 A; |
DIEDERICHS : DCG1084 | Interior Blower | Voltage: 13.5 V; Rated Power: 365 W; Current-carrying capacity: 27 A; Service RPM: 3700 1/min; : for vehicles with air conditioning (manually controlled) ; |
DIEDERICHS : DCG1085 | Interior Blower | Voltage: 13.5 V; Rated Power: 338 W; Current-carrying capacity: 25 A; Service RPM: 3800 1/min; : E-type checked ; : for vehicles with automatic climate control ; |
DIEDERICHS : DCG1086 | Interior Blower | Voltage: 13.5 V; Rated Power: 311 W; Service RPM: 3900 1/min; : for vehicles with air conditioning ; Current-carrying capacity: 23 A; |
DIEDERICHS : DCG1087 | Interior Blower | Voltage: 12 V; Rated Power: 240 W; : for vehicles with air conditioning ; |
DIEDERICHS : DCG1088 | Interior Blower | Voltage: 13.5 V; Rated Power: 311 W; Current-carrying capacity: 23 A; Service RPM: 3800 1/min; : for vehicles with air conditioning ; |
DIEDERICHS : DCG1089 | Interior Blower | Voltage: 13.5 V; Rated Power: 270 W; Service RPM: 3550 1/min; : for vehicles with/without air conditioning ; Current-carrying capacity: 20 A; |
DIEDERICHS : DCG1090 | Interior Blower | Voltage: 13.5 V; : E-type checked ; |
DIEDERICHS : DCG1091 | Interior Blower | Voltage: 13.5 V; Rated Power: 324 W; Current-carrying capacity: 24 A; Service RPM: 3400 1/min; : for vehicles with air conditioning ; Number of connectors: 2 ; |
DIEDERICHS : DCG1092 | Interior Blower | Voltage: 13.5 V; Rated Power: 331 W; Service RPM: 3300 1/min; : for vehicles with/without air conditioning ; Current-carrying capacity: 24.5 A; |
DIEDERICHS : DCG1093 | Interior Blower | Voltage: 13.5 V; Rated Power: 173 W; : for vehicles without air conditioning ; |
DIEDERICHS : DCG1094 | Interior Blower | Voltage: 13.5 V; Rated Power: 256.5 W; Current-carrying capacity: 19 A; Service RPM: 3500 1/min; |
DIEDERICHS : DCG1095 | Interior Blower | Voltage: 13.5 V; Rated Power: 182 W; Service RPM: 3000 1/min; : for vehicles with/without air conditioning ; Current-carrying capacity: 13.5 A; |
DIEDERICHS : DCG1096 | Interior Blower | Voltage: 13.5 V; Rated Power: 155 W; Service RPM: 4250 1/min; : for vehicles with/without air conditioning ; Current-carrying capacity: 11.5 A; |
DIEDERICHS : DCG1097 | Interior Blower | Voltage: 13.5 V; Rated Power: 202 W; Service RPM: 3100 1/min; : E-type checked ; : for vehicles with/without air conditioning ; Current-carrying capacity: 15 A; |
DIEDERICHS : DCG1098 | Interior Blower | Voltage: 13.5 V; Rated Power: 169 W; : for vehicles with/without air conditioning ; Current-carrying capacity: 12.5 A; Service RPM: 3300 1/min; |
DIEDERICHS : DCG1099 | Interior Blower | Voltage: 13.5 V; Rated Power: 270 W; : for vehicles with air conditioning ; Number of connectors: 2 ; Current-carrying capacity: 20 A; Service RPM: 3000 1/min; : E-type checked ; |
联系客服